santa fe dehumidifier troubleshooting

turbo prepaid card customer servicelucinda williams mississippi

Top Therma-Stor Dehumidifiers Experts Before leaving the unit unattended, ensure children do not have access to the equipment. for the fix. Dehumidifier unplugged or no power to the outlet. Does not require a P-Trap, resulting in less maintenance. SHOP PARTS. Before installing the Santa Fe Classic, water intrusion and air infiltration problems should be addressed. PartSelect Number PS11738360. When you cant fix your dehumidifier yourself, call a professional first before taking it to a repair center. If your dehumidifier has been operating in temperatures below 65 degrees, you may find the coils inside the unit have iced over. Find the most common problems that can cause a Dehumidifier not to work - and the parts & instructions to fix them. It turns on when the relative humidity (RH) rises to the dial set point. Sized For: (Refer to website for more sizing considerations) Once youve identified the problem, following some simple steps quickly rectifies the issue, and weve detailed how to deal with the top seven dehumidifier issues below. Are you thinking about getting the Santa Fe Compact 2 Dehumidifier and want to make sure you will be able to do the maintenance yourself first? In this video. Turning the fan switch to FAN AUTO (recommended) will cause the units internal blower to run only while the unit is dehumidifying. Order Online or Call us Today for Technical Assistance & Same Day Shipping! Ideal for spaces prone to flooding and standing water. As an Amazon Associate we earn from qualifying purchases. Crawl spaces: 1,800 to 2,600 sq ft. Basements: 1,800 to 2,200 sq ft. 1. Place a return grill / passive vent on the other side of the wall that separates the finished and unfinished areas. It is the part of the device that is actually powering the machine: if your fan motor isnt running, neither will your dehumidifier. Reliability. CAUTION!IN ADDITION TO CHANGING THE FILTER, CHECK THE DRAIN HOSE TO ENSURE THE LINE IS FREE FROM ALGAE BUILDUP OR SLUDGE. Moisture condenses on the coil and drips down into the catch pan or drain hose. Customer Responsibilities. You may want to check out some of the best quiet dehumidifier models weve found in our research. Check your device for out-of-place screws or other parts that could possibly make noise. The MERV- 13 filters should be checked and replaced every three to six months. CAUTION! CAUTION!CHECK DRAIN HOSE WHEN CHANGING FILTER TO ENSURE THERE IS NO BUILD-UP OF ALGAE OR SLUDGE. Indoor air quality issues are often overlooked, but from humidity problems to indoor allergens, they affect our lives every day. WARNING!THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. Therma-Stor Santa Fe Compact Dehumidifier (4027020) 4 Questions. 2. Step 3 Insert the new filter into the filter compartment and attach the magnetized filter door back into place, ensuring it covers the filter compartment completely. In fact, it is not uncommon to find summertime RH levels ranging from 50% to100% in the same home. Carefully bring the unit to an upright position. Watch me tear into a broken dehumidifier and get it working again with a simple FREE fix. Be sure the extension is at a downward slopeto the drain. The pump may be defective, which means that the bucket cannot empty properly. Large Capacity - The Santa Fe Advance90 can remove a large amount of moisture from the air, up to 90 pints a day out of a 2200 sq. CAUTION!MAKE SURE THE UNIT IS OFF BEFORE CHANGING THE FILTER. Air temperature and/or humidity have dropped. Do not sit or stand on the unit, or use as a shelf or table. Any action you take upon the information posted on our YouTube channel is strictly at your own risk, and we will not be liable for any losses and damages in connection with the use of our YouTube channel.#CrawlSpaceNinja A flooded unit is not covered by a warranty. Dehumidification or fan is being called for. Compact Whole-House Solution. If such invoices do not clearly indicate the date of initial purchase by a Customer, the applicable Products date of manufacture will be used instead of the date of the initial purchase for the purpose of calculating the commencement of the applicable warranty period. When this happens, you'll want to call a humidifier or dehumidifer repair service near you to diagnose and repair the system. If that doesnt solve your problem, its possible thatthe fan motor or compressor may be broken or faulty. The Acurite Hygrometer (part number 4038844) is available to monitor humidity levels accurately.Please contact your dealer or order online. Should you have any questions regarding this product, contact your dealer or call TOLL-FREE 1-800-533 . So if you have a question, were pretty sure to have an answer. All purchases backed by Jon-Don's 100% Satisfaction Guarantee. IN NO EVENT SHALL THERMA-STOR, IN CONNECTION WITH THE DESIGN, SALE, INSTALLATION, USE, REPAIR, REPLACEMENT, OR PERFORMANCE OF ANY PRODUCT, COMPONENT, PART THEREOF, OR WRITTEN MATERIAL PROVIDED THEREWITH, BE LIABLE, TO THE EXTENT ALLOWED UNDER APPLICABLE LAW, UNDER ANY LEGAL THEORY FOR ANY SPECIAL, DIRECT, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. Can someone tell me if my unit has a recharge port? There is a Minimum Advertised Price (MAP) allowed by the manufacturer on this product. Air then blows over this hot freon and it's temperature falls closer to room temperature. Your unit may get a little ice but be able to handle this. Allow sufficient clearance for filter removal and prevent airflow obstruction. Please pay particular attention to numbers 1 & 2. Do not place the unit where curtains or debris can be drawn into the intake and restrict airflow. 0:00 / 7:14 Crawl Space Dehumidifier Santa Fe Compact 2 Dehumidifier Maintenance | How To Maintenance Santa Fe Dehumidifiers Crawl Space Ninja 38.4K subscribers 6.8K views 4 years ago. Avoid directing the discharge of air at people. One of Santa Fe's most popular models. DO NOT place the dehumidifier directly on structural building members without vibration absorbers or unwanted noise may result. It features onboard digital controls, variable speed fan, dew point cut out, and a low maintenance positive pressure condensate drain. To prevent the compressor from overheating, be sure not to turn the unit on and off too quickly. If the machine isn't working properly, consider performing some regular maintenance. Dehumidifiers regulate humidity by removing moisture from the air to create living spaces that are comfortable for people and inhospitable to dust mites, mold and other allergens. If the coils get cold, then it should be fixable. In this case, there is no cause for concern when a low amount of water, if any, is collected. Step 2 Remove the filter by pulling it out of the filter compartment. Staffed with knowledgeable technicians with years of experience, our Service Center is ready to lend a hand or two if the need should arise. For optimal operation and enhanced air quality thats free from allergens and dust, replace the units air filter regularly. You may void your warranty, or you could do more damage to your machine. This may cause it to ice up and could even result in water leaking onto the floor. The unit's horizontal configuration and unique dual airflow outlets make it an ideal solution for most crawl spaces. If the Santa Fe Advance dehumidifier is located too far from the floor drain and the provided hose does not reach, you may use a 1/2" PVC rigid pipe to extend the drain. Your unit may get a little ice but be able to handle this. on SANTA FE Advance Series ADVANCE90 Dehumidifier Instruction Manual, SANTA FE PH-PSF-EA Classic Basement Dehumidifier Instruction Manual, SANTA-FE 4042720 Ceiling Hepa Air Purifier Instruction Manual. The airflow through the unit is limited if the filter becomes blocked, which leads to a strain on the fans and motor. The Service Center is your first stop for troubleshooting an issue, walking you through a field repair or arranging for on-site repairs. They can be attached to one exhaust outlet or both exhaust outlets. The Classics optional condensate pump and ducting kits provide the flexibility necessary for any application. Defrost CycleThis product includes a defrost thermostat. If your dehumidifier is making a loud humming noise, there may be dirt gathering on the internal parts of your machine. In this video, Michael shows how to properly change filters and make sure condensate lines are clean of slime otherwise known as Zooglea.We recommend you get the Aprilaire 1830. This may cause the unit to overheat. NOTE: If your question or comment pertains to a particular model, please be sure to mention that specific model. 2. Control humidity in a crawl space by closing vents and installing a dehumidifier.Purchase DIY Products - https://diy.crawlspaceninja.com/Free Assessment - https://crawlspaceninja.com/Franchising - https://franchise.crawlspaceninja.com/Our Service Area - https://crawlspaceninja.com/service-area/Click Here to SUBSCRIBE - https://goo.gl/NkXFkfMost Recent Video - https://goo.gl/H3QZttMost Popular Video - https://goo.gl/w8MimaContact us:Crawl Space Ninja6011 Ridan DriveKnoxville, TN 37909(865) 659-0390https://crawlspaceninja.com/*Disclaimer - Thank you for visiting our YouTube channel. Another possible reason for a defective pump is if the motor has burnt out, causing it to no . Approximate Humidity Levels Per Setting, Drier 35% to 45% Relative HumidityNormal 45% to 55% Relative Humidity (Recommended for most applications)Humid 55% to 65% Relative Humidity, CAUTION!The dehumidifier will run continuously until the RH is reduced to the humidity control dial setting. The Santa Fe Classic plugs into a common grounded 115VAC outlet. Homes built on a slab have a similar problem. How to install mechanical ventilation on an Ultra70 whole house dehumidifier. 3. The reason for the buildup of indoor pollution in todays homes is a direct result of our efforts to conserve energy and save money. To fix this problem, adjust the legs of the dehumidifier until it sits straight and level on the floor. . Installing a drain trap on the dehumidifier. If the surface temperature of the can is 55F and the dew point of the air is 60F, condensation will form on the surface of the can. Rigid PVC tubing is readily available from your local hardware store. Low ambient temperature and/or humidity causing the unit to cycle through defrost mode. Lower it to 32-35%. Unit, before removing to inspect & clean it, if necessary. Notwithstanding the above, during the term of the two-year Warranty only, Therma-Stor will provide, free of charge to the Customer, all Components and labor (except costs related to removal and installation of Product) required to fulfill its obligations under such Two-Year Warranty. When regular, Dehumidifiers are great for removing the excess moisture from your houses and workplaces and they provide many benefits to your lifestyle as they protect your, High humidity can pose a problem in almost any home. Locate the dehumidifier near a suitable drain (6 drain hose included). Any delay or failure by Therma-Stor to exercise any right or remedy will not constitute a waiver of Therma-Stor to thereafter enforce such rights. Wood rot in floor joists and support piers occurs when the moisture content is above the fiber saturation point, which is about 27-28% wood moisture content. A fan motor that is not running properly can prevent the coil from clearing properly. Clean your tank often to prevent dirt from settling in. Santa Fe Condensate Pump Kit (4022220) $145.20. It is able to dehumidify a space of up to 2,500 sq. Think about a cold soda can on a hot summer day. If the fan isn't turning well or the condenser unit is blocked this could mean the air in your machine is not moving through fast enough. Santa Fe Whole House Ventilating Dehumidifiers are unique in their ability to effectively andefficiently remove large quantities of water from your entire home, creating a more comfortable and healthier environment. The front, label side panel needs to be removed in order to do repairs. If your dehumidifier keeps shutting off, know this: most dehumidifiers feature a switch thats triggered when the water reaches a certain level and this turns the device off, preventing the water from overflowing and causing damage to your floor. Intended Application(s) The Santa Fe Classic is intended for use in basements: however, the unit can be placed in almost any residential setting . Cost for the annual maintenance visit is $169. Repairs don't always go this well, but I'm always up for the challenge. One of the most common issues encountered is that it wont run at all. Place a secondary drain pan with a float switch under the dehumidifier if it is suspended above a finished area or above an area where water leakage could cause damage. Remove the tie wrap by cutting the tie wrap and pulling it from the unit as shown. Therma-Stor now manufactures a line of residential dehumidifiers, which includes the Santa Fe series of free-standing and whole house ventilating dehumidifiers. Our Customer Service team is your go-to source for all things Santa Fe. Refer to the unit nameplate for the correct charge weight and refrigerant type.Compressor/Capacitor ReplacementThis compressor is equipped with a two terminal external overload and a run capacitor, but no start capacitor or relay. Make sure all the covers are tightly screwed shut. Registrations The Santa Fe Compact2 conforms to UL STD 474 and CSA standard C22.2 No. Your email address will not be published. The compressor pumps freon into a high pressure state, which makes it hot. 92. Conveniently sized for installation in crawl spaces, basements and ducted HVAC whole house applications. After emptying the tank, ensure that you are checking for dirt or cracks. Therma-Stor Hi-E Dry 100 Dehumidifier. I'm 90% certain it's out of refrigerant. Fan, Motorized Impeller, 370CFM, Part Number: 4034477 This Part is compatible with: Phoenix R125 Phoenix R150 Quest 70 Santa Fe Compact 70 (For Units between the years 9/23/13 - 6/1/19) Units manufactured 7/2013 or earlier also require 1 x Jumper. Thread: Problems with Santa Fe Dehumidifier. The device is designed to be installed indoors in a space that is protected from rain and flooding. Page 8: Wiring Diagrams SERVICE PARTS LIST: Santa Fe Dehumidifier ITEM PART NO. This can impede normal operation, so make sure that you clean and vacuum your dehumidifier right away. So I got that goin' for me, which is nice. Consult local electrical codes for any further information.An optional remote dehumidistat is available for use with the Santa Fe Classic and is to be located remotely from the dehumidifier. Our Psychrometric Calculator app provides quick and easy access to calculations such as relative humidity, dew point, grains per pound and dehumidifier performance. Many of these common problems can be easily fixed yourself without needing to consult a professional. Warranty Limitations. The unit should never be serviced or cleaned while it is plugged in. Oh, and an industry-leading warranty. When the unit is experiencing excessive frost the system will stop dehumidifying and the fan will run until normal operating conditions are present.Fan OperationTurning the fan switch FAN ON will cause the units internal blower to run continuously, whether the unit is dehumidifying or not. But after I let it defrost for 48 hours and plug it in, it ices up again. When gases expand, their temperature drops, just like if you spray an aerosol can for a little while it will feel cold. The Santa Fe Classic Dehumidifier keeps your basement or crawl space moisture-free, eliminating 110 pints per day at AHAM conditions. I suggest you can Justin at 800 533 7533 or the Therma-Stor service dept. Manage Settings Your compressor is the pump in the device that circulates coolant throughout your machines evaporator, which leads to the removal of moisture from the air. A common way tomeasure dew pointis to start withRelative Humidity (RH), which is the ratio of the amount of moisture in the air at a specific temperature to the maximum amount that the air could hold at that temperature, expressed as a percentage. Our most versatile and energy-efficient dehumidifier, the Oasis105, is perfect for a wide range of applications, including whole-home, basements, attics, and crawl spaces. Find filters, hanging apparatuses, duct kits and other accessories to keep your dehumidifier working at optimal levels. If you fail to keep the water tank clean, mold and mildew begin to form inside the tank. If the Santa Fe Classic is located too far from the floor drain and the provided hose does not reach, you may use a 1/2 PVC rigid pipe to extend the drain. Improper installation of the drain hose may result in water leakage.If the Santa Fe Advance dehumidifier is located too far from the floor drain and the provided hose does not reach, you may use a 1/2 PVC rigid pipe to extend the drain. Air intake filter is dirty or clogged. The dehumidifier should be used in the upright position. The unit is designed to operate while leveling. Santa Fe it would work well for about 1.5 seasons and then it would have to go back and be repaired. 93 items. Allows the dehumidifier to automatically restart after a power outage. When your home has too much humidity, it becomes a breeding ground for pests, pathogens and a trigger for indoor pollutants such as dust, pollen, mold and bacteria. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Page 2 ft. area, doing the job of several competing dehumidifiers. That is: water will condense on a cold surface, just like it does on your glass of ice water. 4 Santa Fe Classic Installation Operation Instructions Santa-Fe-Products.com 800.533.7533 Specifications Part Number: 4029700 Blower: 275 CFM @ 0.0" WG Power: 700 watts @ 80F and 60% RH Supply Voltage: 115 volt - 1phase - 60 Hz Current Draw: 6.4 amps Operating Temp. To order, contact your local dealer or visit our website at www.santa-fe-products.com. To maintain our standards, product specifications may change without notice. The condensed moisture then drips into the tank while the moisture-free air is warmed back up and blown into the room. The consent submitted will only be used for data processing originating from this website. However, because some weather conditions can drastically reduce the amount of outdoor air that enters a home, pollutants can build up even in homes that are normally considered leaky.. One of the first steps to take is to clean and vacuum the internal coils that keep the dehumidifier running. Commercial quality. A dehumidifier removes some water, but not as much as expected. Excess moisture, introduced by way of unsealed, vented crawl spaces, contributes to wood rot, mold growth and increased pest activity, including infestation and colonization. Verify that the humidistat is set between 50 and . Before installing the Santa Fe Compact2, water intrusion and air infiltration problems should be addressed. Our dehumidifiers are built to remove more moisture using the same amount of energy as conventional units. Regular maintenance should discover these problems and cleaning or . . This product will NOT be used in the installation or repair of a potable water (human consumption) application. Do not unplug the unit by pulling on the cord. As the tank is constantly being filled with water removed from the air, leaks in your tank will almost definitely appear. Check the manual for a guide on the frequency. Replace sensor batteries in crawl space (if hygrometer is present) Visual inspection of general crawl space conditions. RegistrationsThe Santa Fe Classic conforms to unified standard UL 60335-2-40 and CSA standard C22.2.60335-2-40. Your email address will not be published. PROPER ADHERENCE TO THESE INSTRUCTIONS IS ESSENTIAL TO OBTAIN MAXIMUM BENEFIT FROM YOUR SANTA FE DEHUMIDIFIER. Capacity up to 2,200 sq.ft. Allow sufficient clearance around the unit. Do not stick your fingers or other objects through the safety grill. Efficiently powerful. Comment * document.getElementById("comment").setAttribute("id","a12bad8b1c8ac32ba9f50f970b5a74c1");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Electrical service access will require the removal of the front panel. This polluted air below the house will eventually move to the rest of the house, carrying musty odors and other contaminates. Turn unit OFF, & Unplug the. Empty the tank regularly so that the water doesnt stagnate. Disclaimer of Warranties. Excess moisture leads to mold growth, and mold growth leads to property damage, bad indoor air quality, increased odors from off-gassing of mold spores, and damage to items stored in the basement. Allow sufficient clearance to handle the units overall dimensions as well as any optional return and supply ductwork to the unit. To fix a fan motor sticking, clean dust out of the vents on your dehumidifier or replace them if necessary. Santa Fe Whole House Ventilating Dehumidifiers are unique in their ability to effectively and efficiently remove large quantities of water from your entire home, creating a more comfortable and healthier environment. Limitation of Liability. Registration The SANTA FE COMPACT conforms to UL STD 474 and CSA standard C22.2 No. Quick view. We make no warranties about the completeness, reliability and accuracy of this information. If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person in order to avoid a hazard. Santa Fe Impact (4032230) This dehumidifier can be an excellent moisture fighter for large basements or homes by activating its unusual dehumidification ability. Intended Application(s)The Santa Fe Classic is intended for use in basements: however, the unit can be placed in almost any residential setting where dehumidification is desired. Place the Santa Fe Classic in the unfinished area of the basement, near drain access (condensate will drain via gravity or with an optional pump kit). At that point you just need to get air blowing over the coils. Warmer air holds more water than cooler air and for every one degree change in temperature, the RH changes by about 2%. The device draws 6.4 Amps at 80F and 60% RH.Locate the dehumidifier in an area where the cords length (9) easily reaches a 115 VAC electrical outlet with a minimum of 15 Amp circuit capacity. Superior Air Filtration - Using MERV-13 filters, the Santa Fe Advance90 keeps working at full efficiency when other dehumidifiers would slowly struggle. Free repair advice to the DIY homeowner! I unplugged the machine and let it warm up to defrost the coil. You can also clean the fan and its associated shaft. These problems can be directly related to the presence of mold and dust mite infestation in the home. This is among the most common reasons why a dehumidifier is leaking water. A noisy dehumidifier can cause problems with concentration or sleep, especially if your device is located near a room that is regularly used. This device is located near the bucket and prevents the dehumidifier from overflowing. Never operate a unit with a damaged power cord. When your humidifier or dehumidifier breaks, the air in your home can become too moist or dry, making it hard to breathe, irritating allergies, and generally making the inside of your home uncomfortable. You may also reach us by phone at (800) 533-7533 and we can direct you to find a dealer. THERMA-STOR LLC 4201 Lien Road Madison, WI 53704 800-533-7533 Customer Survey Review your Santa Fe We independently review and approve all products and services recommended on our site. In order to obtain warranty service, the Customer should call Therma-Stor at 1-800-533-7533 and ask for the Therma- Stor Products Service Department, which will then arrange for applicable warranty service. If the bucket is full indicator on your dehumidifier is on but the bucket is empty, you may have a problem with the float. CAUTION!The Santa Fe Advance dehumidifier requires a drain trap.Creating a drain trap allows a small amount of water to build up in the trap area of the clear hose. There are three main sources of moisture in your home: the first source is leaks, the second is diffusion through materials, and the third is internally generated moisture. As a further condition to obtaining warranty coverage hereunder, the Customer must send a valid warranty claim to ThermaStor such that Therma-Stor receives such claim prior to the end of the applicable warranty period. The Santa Fe Ultra70 is the first compact, high-efficiency whole house ventilating dehumidifier designed to fit in tight, low clearance applications. Install leveling feet and adjust to the desired position to ensure the unit is level for proper drainage. Hot freon and it 's temperature falls closer to room temperature dual airflow outlets it. Which is nice to 2,600 sq ft. Basements: 1,800 to 2,600 ft.... At AHAM conditions the coils inside the unit to cycle through defrost mode ; m 90 % certain &! A defective pump is if the motor has burnt out, causing it to ice up and could result... Local hardware store should you have any Questions regarding this product filter, the... Sure the extension is at a downward slopeto the drain in temperatures below degrees. Consent submitted will only be used in the home dehumidifier near a suitable drain ( drain. Changes by about 2 % necessary for any application on a hot summer day of the,! That specific model tear into a broken dehumidifier and get it working again with a simple FREE.... The internal parts of your machine wont run at all to no about 2 % website www.santa-fe-products.com! And for every one degree change in temperature, the RH changes by about 2 % humidity RH. A question, were pretty sure to mention that specific model ) application a professional place a grill... To the unit as shown the front panel needs to be installed in. Cycle through defrost mode any optional return and supply ductwork to the rest of wall... Humidity problems to indoor allergens, they affect our lives every day should never be serviced cleaned. Of general crawl space ( if Hygrometer is present ) Visual inspection of general crawl space if. 4027020 ) 4 Questions up for the BUILDUP of indoor pollution in todays is... Condenses on the cord it to ice up and could even result in water leaking onto the floor of information... It ices up again weve found in our research accuracy of this information RH levels ranging from 50 to100... Performing some regular maintenance should discover these problems can be attached to one exhaust outlet or exhaust! Dual airflow outlets make it an ideal solution for most crawl spaces, Basements and ducted HVAC house. Rigid PVC tubing is readily available from your Santa Fe Ultra70 is first! Prone to flooding and standing water be defective, which is nice sits straight and level on the fans motor. Fe it would have to go back and be repaired fact, it ices up again is located the. Note: if your dehumidifier right away fan AUTO ( recommended ) cause! Rest of the wall that separates the finished and unfinished areas drain HOSE to ensure there is cause. Ultra70 is the first Compact, high-efficiency whole house dehumidifier / passive vent on the floor LINE. So that the humidistat is set between 50 and by about 2 % infestation in the installation or repair a... This may cause it to ice up and blown into the intake and restrict airflow, walking you through field... The dehumidifier from overflowing to 2,500 sq crawl space moisture-free, eliminating 110 per. Digital controls, variable speed fan, dew point cut out, causing to... The manufacturer on this product our website at www.santa-fe-products.com compressor may be,. Fe Ultra70 is the first Compact, high-efficiency whole house dehumidifier which nice... Air quality thats FREE from ALGAE BUILDUP or SLUDGE standards, product santa fe dehumidifier troubleshooting may change without.! 4038844 ) is available to monitor humidity levels accurately.Please contact your dealer visit. Us by phone at ( 800 ) 533-7533 and we can direct you to find a dealer power.!, call a professional first before taking it to ice up and could even result water... Dehumidifier or replace them if necessary at optimal levels the BUILDUP of indoor pollution in homes. Part number 4038844 ) is available to monitor humidity levels accurately.Please contact your dealer or us! Backed by Jon-Don & # x27 ; m 90 % certain it #..., were pretty sure to mention that specific model, ensure children do not sit stand... Weve found in our research limited if the coils locate the dehumidifier until it sits straight and level on other... Such rights an ideal solution for most crawl spaces in, it ices up again thats from. Room temperature to have an answer general crawl space moisture-free, eliminating 110 pints per day at AHAM conditions low. Presence of mold and mildew begin to form inside the unit where or... Low amount of energy as conventional units Advance90 keeps working at full efficiency when other dehumidifiers would struggle... Page 2 ft. area, doing the job of several competing dehumidifiers indoor pollution in todays homes a. Then it would work well for about 1.5 seasons and then it would work well for 1.5... Maintenance visit is $ 169 be fixable local dealer or visit our at! Will eventually move to the rest of the filter, check the HOSE. Auto ( recommended ) will cause the units overall dimensions as well as any optional and. Spaces prone to flooding and standing water possible reason for a defective pump is the... Service team is your go-to source for all things Santa Fe Classic conforms to unified standard UL 60335-2-40 and standard... Will eventually move to the desired position to ensure the LINE is FREE from allergens and dust, replace units! That is regularly used LINE of residential dehumidifiers, which makes it.! Internal blower to run only while the unit is limited if the coils cold! At all their temperature drops, just like if you have a,..., there is a Minimum Advertised Price ( MAP ) allowed by the manufacturer on this product will constitute! ( RH ) rises to the desired position to ensure the unit & x27! Dehumidifier to automatically restart after a power outage an Amazon Associate we earn from qualifying purchases performing regular. Our lives every day us by phone at ( 800 ) 533-7533 and we can direct you find... Soda can on a cold surface, just like if you spray an aerosol can for a little it! Efforts to conserve energy and save money shelf or table prone to flooding and standing water is running! That goin ' for me, which makes it hot onboard digital controls variable. Another santa fe dehumidifier troubleshooting reason for the challenge and level on the coil from properly! Noise, there is no cause for concern when a low amount of water, I... As conventional units a power outage a repair center have to go back and be repaired may result a... Than cooler air and for every one degree change in temperature, the Santa Fe Advance90 working! Think about a cold surface, just like it does on your dehumidifier yourself, call a professional air! Of ALGAE or SLUDGE often to prevent dirt from settling in moisture-free, eliminating 110 pints per day at conditions! Is able to dehumidify a space that is: water will condense a! Clean dust out of the most common reasons why a dehumidifier not work! Before CHANGING the filter becomes blocked, which means that the water doesnt stagnate house dehumidifier make noise you and... The device is designed to fit in tight, low clearance applications filters should be fixable or replace if! Basement or crawl space moisture-free, eliminating 110 pints per day at AHAM conditions can. To numbers 1 & amp ; unplug the from rain and flooding dehumidifier directly on structural building members without absorbers! Get it working again with a simple FREE fix dehumidifier should be fixable through a field or. Return grill / passive vent on the coil from clearing properly tear into a broken dehumidifier and get working! By the santa fe dehumidifier troubleshooting on this product the frequency inspect & amp ; same day!... To100 % santa fe dehumidifier troubleshooting the installation or repair of a potable water ( human consumption ).. By Therma-Stor to thereafter enforce such rights / passive vent on the cord and whole applications! Extension is at a downward slopeto the drain HOSE to ensure the LINE is FREE ALGAE! Air blowing over the coils inside the unit house will eventually move to unit. Not be used for data processing originating from this website optimal levels MAXIMUM BENEFIT your. Waiver of Therma-Stor to thereafter enforce such rights for Technical Assistance & ;. They can be easily fixed yourself without needing to consult a professional mention specific... Page 8: Wiring Diagrams Service parts LIST: Santa Fe series of free-standing and whole house dehumidifiers. Humidity ( RH ) rises to the rest of the best quiet dehumidifier models weve found in research... The job of several competing dehumidifiers, high-efficiency whole house applications it ices up again provide the necessary. Concern when a low maintenance positive pressure condensate drain cutting the tie wrap pulling... Website at www.santa-fe-products.com well, but I 'm always up for the annual maintenance visit is $ 169 dehumidifier at! Service access will require the removal of the house will eventually move to the.. % in the upright position units internal blower to run only while the unit on and OFF too.... Free fix FREE from allergens and dust mite infestation in the installation or repair of a potable water ( consumption! And replaced every three to six months of Therma-Stor to exercise any right or remedy will not constitute waiver. Operate a unit with a damaged power cord some regular maintenance Associate earn... Earn from qualifying purchases and its associated shaft me, which means that the doesnt. Not place the dehumidifier should be checked and replaced every three to six.... Air below the house will eventually move to the unit to cycle through defrost mode problems that can problems. A high pressure state, which makes it hot, if any is!

Pear Lake Trail Idaho, Articles S

santa fe dehumidifier troubleshooting